Technical specification
Supply voltage: 8-32V DC, 6-24V AC Operating temperature range: -40°C - +85°C Max. current consumption (@24V): 75 mA Number of switched output(s): 2 unfused relay contact (NO) Max. load current on output(s): 1A@24V DC, 0.5A@125V AC Max. switched voltage: 125V AC, 60V DC Number of open detection inputs: 2 detection inputs Input voltage short circuit protection: fuse (0.2A) Size: 40x80x20 mm Wireless communication protocol: Bluetooth 4.0 LE RF carrier frequency: 2.4GHz RF TX power: +4 dBm
OUT1 First output of the device. Should be connected to the appropriate input of the main unit of the gate system (type: dry contact)
OUT2 Second output of the device. Should be connected to the appropriate input of the main unit of the gate system (type: dry contact)
IN1 First input of the device for detecting closed position of the controlled gate in association with OUT1(optional).
IN2 Second input of the device for detecting closed position of the controlled gate in association with OUT2(optional).
NC Not connected. Reserved for future use.
PWR Power supply input of the device (polarity independent)