Supply voltage: 8-32V DC, 6-24V AC
Operating temperature range: -40°C - +85°C
Max. current consumption (@24V): 75 mA
Number of switched output(s): 2 unfused relay contact (NO)
Max. load current on output(s): 1A@24V DC, 0.5A@125V AC
Max. switched voltage: 125V AC, 60V DC
Number of open detection inputs: 2 detection inputs
Input voltage short circuit protection: fuse (0.2A)
Size: 40x80x20 mm
Wireless communication protocol: Bluetooth 4.0 LE
RF carrier frequency: 2.4GHz
RF TX power: +4 dBm



OUT1
First output of the device. Should be connected to the appropriate input of the main unit of the gate system (type: dry contact)

OUT2
Second output of the device. Should be connected to the appropriate input of the main unit of the gate system (type: dry contact)

IN1
First input of the device for detecting closed position of the controlled gate in association with OUT1(optional).

IN2
Second input of the device for detecting closed position of the controlled gate in association with OUT2(optional).

NC
Not connected. Reserved for future use.

PWR
Power supply input of the device (polarity independent)